The TDR2000/3 and TDR2010 advanced dual-channel time domain reflectometers have been designed for the location of faults in communication and pilot cables and some power supplies. They are tough, rated CAT IV to 150 V, and are dust and weatherproof to IP54, making them ideal for working in the field.


Features such as 'Auto setup' help you to get useful traces fast, while the 'AutoFind' fuction assists you with the interpretation of the traces. If you're an expert user, you can manually override the auto function allowing you to fine tune the instrument to identify hard-to-determine faults. What's more, the new screen layout enables you to overlay traces, assisting in the location of faults.

Range:

m | ft | ns

10 | 30 | 125

25 | 80 | 250

50 | 160 | 500

100 | 320 | 100

250 | 800 | 2500

500 | 1600 | 5000

1000 | 3200 | 10000

2500 | 8000 | 25000

5000 | 16000 | 50000

10000 | 32500 | 100000

20000 | 65000 | 200000

Accuracy: ±1% of range ± 1 pixel at 0.67 VF

Resolution: 1% of range

Refresh rate: Trace updates 3 times per second

Output pulse: Up to 20 volts peak to peak into open circuit. Pulse widths determined by range and cable

Gain: Set for each range with three user selectable steps (in manual operating mode)

Velocity factor: Variable from 0.2 to 0.99 in steps of 0.01

TX null: 

Automatic 

Trace Tagging - 32 characters chosen from upper case letters including accents

Colour schemes - Default, Outdoor, Custom

Step TDR - Eliminates the Dead Zone effect

DDG - Available in ranges 1000 m and above in 0.5 dB steps

Cable Impedance - 25, 50, 75, 100, 125 ohm + AUTO.


Share by: