The MTR105 rotating machine tester is a dedicated static motor tester with Megger’s tried and trusted suite of insulation resistance tests (IR), plus all the great traditional features and reliability of Megger’s testers.


The MTR105 takes the test abilities of Megger’s proven IR test instruments adding DLRO four wire Kelvin low resistance test, inductance, and capacitance tests to provide a versatile motor tester, all packaged in a robust handheld instrument. Additionally, the MTR105 incorporates temperature measurement and compensation (for IR tests), motor direction of rotation, and supply phase rotation tests.


What's more, the MTR105 has been designed to be exceptionally safe to use. The fast detecting circuitry reduces the likelihood of damage to the instrument if accidentally connected to live circuits or across phases.

Insulation resistance

Volts | Accuracy

50 V | 10 GΩ ±2% ±2 digits ±4.0% per GΩ

100 V | 20 GΩ ±2% ±2 digits ±2.0% per GΩ

250 V | 50 GΩ ±2% ±2 digits ±0.8% per GΩ

500 V | 100 GΩ ±2% ±2 digits ±0.4% per GΩ

1000 V | 200 GΩ ±2% ±2 digits ±0.2% per GΩ

Polarisation index (PI): 10 min / 1 minute ratio

Dielectric absorption ratio (DAR): User configurable 15 s or 30 s t1 start time with t2 fixed at 60 s

Guard terminal performance: <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load

Resolution: 0.1 kΩ

Short circuit/charge current: 2 mA +0% -50 (IEC61557-2)

Terminal voltage accuracy: -0% +2% ±2 V

Test current: 1 mA at min. pass value of insulation

to a max. of 2 mA

Operation range: 0.10 MΩ to 1.0 GΩ (IEC61557-2)

Leakage current display: 0.1 uA resolution 10% (±3 digits)

Voltage display: ±3% ±2 digits ±0.5% of rated voltage


Continuity

Measurement: 0.01 Ω to 1 MΩ (0 to 1000 kΩ analogue scale)

Accuracy: 

±3% ±2 digits (0 to 99.9 Ω )

±5% ±2 digits (100 Ω - 500 kΩ)

Test current: 

200 mA (–0 mA +20 mA)

(0.01 Ω - 4 Ω)

Polarity: Single or Dual (factory default) polarity

Lead resistance: Null up to 10 Ω

Selectable current limit: 20 mA and 200 mA


Capacitance

Range: 0.1 nF - 1 mF

Accuracy: ±5.0% ±2 digits (1 nF - 10 μF)


Voltmeter

Range:

dc: 0 - 1000 V

ac: 10 mV - 1000 V

TRMS sinusoidal (15 Hz - 400 Hz)

Accuracy: 

dc: ± 2% ±2 digits (0 - 1000 V)

ac: ± 2% ±2 digits

(10 mV - 1000 V TRMS)

Frequency range: 15 - 400 Hz (50 mV - 1000 V)

Frequency resolution: 0.1 Hz

Frequency accuracy: ±0.5% ±1 digit

Diode Test:

Diode test accuracy: ±2% ±2 digits

0.01 V to 3.00 V

Display range: 0.00 V to 3.00 V


Temperature measurement and compensation

Thermocouple: Type T (Type K and Type J)

Thermocouple range: -20 °C to 200 °C (4 °F - 392 °F)

Instrument range: -20 °C to 1000 °C (4 °F - 1832 °F)

Instrument resolution: 0.1 °C (0.18 °F)

Instrument accuracy: 

±1.0 °C ±20 digits (1.8 °F). (Basic accuracy stated assumes forward and reverse measurements.)


DLRO four wire Kelvin low resistance

Test current: 200 mA dc

Range: 1 mΩ to 10 Ω

Resolution: 0.01 mΩ

Accuracy: ± 0.25% rdg. ± 10 digits, accuracy stated includes forward and reverse measurements.


Inductance

Instrument accuracy

Range | Accuracy | Test Frequency

1 H | ±(0.7 % +(Lx/10000) % +5 digits) | 1 kHz

200 mH | ±(1.0 % +(Lx/10000) % +5 digits) | 120 Hz

200 mH | ±(0.7 % +(Lx/10000) % +5 digits) | 1 kHz

20 mH | ±(2.0 % +(Lx/10000) % +5 digits) | 120 Hz

20 mH | ±(1.2 % +(Lx/10000) % +5 digits) | 1 kHz

2 mH | ±(2.0 % +(Lx/10000) % +5 digits) | 1 kHz only


Results storage

Storage capacity 256 motor results (date / time stamped)

Data download: USB Type A (USB Mass Storage Device)