VIBXPERT EX

VIBXPERT EX is a high-performance, intrinsically safe, fully-featured data collector, vibration analyzer and field balancer for easy condition monitoring and troubleshooting of rotating equipment in explosive environments such as petrochemical plants, refineries, offshore oil rigs, etc.
VIBXPERT EX collects field data including vibration information, bearing condition, inspection and process data and seamlessly integrates with the OMNITREND Center software platform for in-depth analysis.
The modular firmware structure allows you to upgrade the VIBXPERT EX from a route data collector to a full-blown troubleshooting device with advanced features such as coast down/run-up measurements, event recording, ODS & modal analysis and cross-channel phase measurement.
It is also possible to connect the VIBXPERT EX to protection systems via the buffered outputs. This enables you to perform additional analysis such as shaft vibration, shaft centerline plots or orbits e.g. on turbines, compressors and other turbomachinery.
As with all our data collectors and vibration analyzers, you will benefit from free software and firmware updates, and low ownership cost.
Input
Analog, Vibration, 2x:
Voltage (AC/DC, ±30 V max.)
Current (AC/DC, ±30 mA max.)
IEPE-type accelerometer (2 mA, 24 V max.)
Current Linedrive (CLD) accelerometer (10 V, 10 mA max.)
Frequency range: DC ... 51.2 kHz (Acceleration from 0.5 Hz)
Dynamic range: 96 dB (measurement) / 136 dB (total)
Sampling frequency: Up to 131 kHz per channel
Impedance: 90 kOhm, with cable VIB 5.433
Analog, Temperature, 1x: Thermocouple (type K)
Digital, Pulse/ Tacho, 1x: RPM, Trigger, Keyphaser with pulse and AC signals: 0 V ... +26 V or -26 V ... 0 V
Max. input voltage: ± 26 V
Switching threshold for 0 V ...+26 V signal: max. 2.5 V rising, min. 0.6 V falling
Switching threshold for -26 V ...0 V signal: min. -8 V rising, max. -10 V falling
Pulse width: < 0.1 ms
Output
Stroboscope control: TTL
Frequency range: 0 - 500 Hz
Resolution: 0.05 Hz
Signal-Out: Connection for headphones to listen to the analog input signal; signal processing (oscilloscope)
Frequency range: 0.5 Hz - 40 kHz
Output impedance: 100 Ohm
Measurement range / Accuracy
Vibration acceleration: Depends on the sensor connected
Shock pulse: -10 ...80 dBsv / ± 3dBsv
RPM: 10 ... 200 000 min-1 / ±0.1‰ or ± 1 min-1 (the lower accuracy is applicable)
Temperature, type K: -50 ... +1000°C / 1% or ±1°C (the lower accuracy is applicable)
Standards fulfilled: Frequency response acc to ISO 2954
Power supply
Battery type: Li Ion rechargeable battery pack (7.2V / 4.8Ah - 34 Wh)
Charging time: < 5 hours in the instrument
Charger, input: 110-240 V / 50-60 Hz
Computer
Processor: Intel Strong ARM 206 MHz
Memory: Internal: 64 MB RAM; Compact Flash: 1 GB or 4 GB
Serial interface: RS 232, <115 kBaud
USB interface: USB host for printing; USB slave for data exchange with OMNITREND
Ethernet interface: 10 Mbit (10Base T), 10 Mbit (10Base T)